{"id":4100,"date":"2025-02-02T08:42:37","date_gmt":"2025-02-02T08:42:37","guid":{"rendered":"https:\/\/saferoadlogistic.com\/?post_type=product&#038;p=4100"},"modified":"2025-02-02T08:42:42","modified_gmt":"2025-02-02T08:42:42","slug":"jb-qg-505-fire-alarm-controller-linkage-type","status":"publish","type":"product","link":"https:\/\/saferoadlogistic.com\/fa\/product\/jb-qg-505-fire-alarm-controller-linkage-type\/","title":{"rendered":"JB-QG-505 Fire Alarm Controller (Linkage Type)"},"content":{"rendered":"<table class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"568\" style=\"width:425.7pt;\">\n<tbody>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Main power<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">AC 220V (+10%<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff5e<\/span><span style=\"font-size:7.5pt;\">-15%) <\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff0c<\/span><span style=\"font-size:7.5pt;\">50HZ<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Secondary power supply (backup power)<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">DC 24V, 17AH<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Power consumption<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Monitoring state: \u2264 3W; Alarm state:\u226410W (25<br \/>\n  detectors are in fire state at the same time)<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Basic monitoring capacity<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">1 loop, capacity 250 points<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">External control unit<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">5 units<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">External control unit contact capacity<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">DC 30V<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff0c<\/span><span style=\"font-size:7.5pt;\">1A.<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Inspection cycle<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">\u2264 10 seconds (single point continuous inspection in<br \/>\n  case of abnormal situation)<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Signal transmission distance<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">\u22641000 meters (RVS-2\u00d71.0mm2);<br \/>\n\u22641500 meters (RVS-2\u00d71.5mm2)<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Alarm line wiring<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Two buses<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Alarm bus voltage<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">24V (18V<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff5e<\/span><span style=\"font-size:7.5pt;\">26V)<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Dimensions<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">365mm\u00d789mm\u00d7305mm<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff08<\/span><span style=\"font-size:7.5pt;\">L\u00d7W\u00d7H<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff09<\/span><span style=\"font-size:7.5pt;\"><\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Operating temperature<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">0<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\u2103<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff5e<\/span><span style=\"font-size:7.5pt;\">55<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\u2103<\/span><span style=\"font-size:7.5pt;\"><\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Relative humidity<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">\u226495%<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Black box record number<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Can save the latest 999 records (including start,<br \/>\n  shutdown, reset, fire alarm, supervision, linkage and fault alarm and other<br \/>\n  information).<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Linkage programming<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">100 (including or 1 logic, or 2 logic, and logic).<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Position conversion capacity<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">1\u00d7250,<br \/>\nEach 10 Chinese characters or 20 English characters<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Fire alarm output relay<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">1 pair (KA1, KA2),<br \/>\nPassive contact, closed in case of fire<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Fire alarm delay output relay<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">1 pair (DA1, DA2),<br \/>\nPassive contact, delayed closing after fire<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Fault output relay<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">1 pair (YA1, YA2),<br \/>\nPassive contact, closed in case of fault<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"227\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">Dimensions<\/span>\n\t\t\t\t<\/p>\n<\/td>\n<td width=\"340\" style=\"background:white;\">\n<p class=\"MsoNormal\" align=\"center\" style=\"text-align:center;\">\n\t\t\t\t\t<span style=\"font-size:7.5pt;\">365mm\u00d7305mm\u00d789mm<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff08<\/span><span style=\"font-size:7.5pt;\">L\u00d7W\u00d7H<\/span><span style=\"font-size:7.5pt;font-family:\u5b8b\u4f53;\">\uff09<\/span><span style=\"font-size:7.5pt;\"><\/span>\n\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<ul class=\"hidden\">\n<li>\n<p class=\"MsoNormal\">\n\tProduct Features\n<\/p>\n<p class=\"MsoNormal\">\n\t\u00a0\n<\/p>\n<p class=\"MsoNormal\">\n\tHigh-performance<br \/>\nembedded processor and embedded real-time operating &#8230; <\/p>\n","protected":false},"featured_media":3533,"comment_status":"open","ping_status":"closed","template":"","meta":{"nf_dc_page":""},"product_brand":[],"product_cat":[160],"product_tag":[],"class_list":{"0":"post-4100","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-fire-alarm-system-controller","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/product\/4100","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/comments?post=4100"}],"version-history":[{"count":1,"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/product\/4100\/revisions"}],"predecessor-version":[{"id":4122,"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/product\/4100\/revisions\/4122"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/media\/3533"}],"wp:attachment":[{"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/media?parent=4100"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/product_brand?post=4100"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/product_cat?post=4100"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/saferoadlogistic.com\/fa\/wp-json\/wp\/v2\/product_tag?post=4100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}